MLD-3500H Tracer gas detector

MLD-3500H Tracer gas detector

MLD-3500H is a professional tracer gas detection instrument used to locate defects in pipes or machinery that cannot be detected with other systems. Tracer gas is a mixture of 5% hydrogen + 95% nitrogen and allows you to work in total safety. The extended measuring range tracer gas detector MLD-3500H makes it the most comprehensive and flexible instrument on the market.

  • Solid Sensors
  • Hydrogen selective ppm sensor
  • Large graphic display
  • Simple and intuitive menu
  • Tracer gas measuring range
  • or tracer gas 1 ppm at 5% VOL
  • Low running costs
  • Excellent Quality/Price ratio

MLD 3500H is a tracer gas detector. By inserting tracer gas into the pipe, it is possible to detect its escape from empty or water-filled pipes. Tracer gas is a mixture of 5% hydrogen + 95% nitrogen and allows you to work in total safety. Tracer gas makes it possible to detect even the smallest defects in pipes.
Increasing the charge pressure of tracer gas in the pipe to be inspected allows to speed up the detection of the defect point. Gastech tracer gas detection technology allows tracer gas to be detected from a few ppm to 5% VOL.

System Description

A robust aluminium housing encloses highly refined microprocessor electronics, and the flexible probe makes it possible to reach hard-to-reach places such as taps, threads or recessed meters. The clear graphical display allows precise detection of tracer gas or tracer gas from ppm to % VOL.

MEASUREMENT SYSTEM
Gas DetectedCH₄Hydrogen calibration (5% contained in tracer gas)
Measurement Scalesppm –% VOL
ZeroingManual and Automatic
ScalesTypeRangeResolutionUncertaintyBottom ScaleTime
of Response
ppm 1Semiconductor0 – 1.000 ppm5 ppm± 5 % f.s.1.000 ppm< 1 sec
ppm 2Semiconductor0 – 10.000 ppm50 ppm± 5 % f.s.10.000 ppm< 1 sec
% VOLThermal conductivity0 – 1.000 % VOL1% VOL± 5 % f.s.100 %Vol< 7 sec
DISPLAY AND ALARMS
DisplayDigital graphic 164×48
Escape Indication4 LEDs plus numeric indication on display
AlarmsSwitchable optical and acoustic alarm
Acoustic Signal Level85 dB (A)
SUCTION SYSTEM
SamplingSuction with built-in electric micro-pump
Suction flow rate1,5 lt/min
Filters on SuctionInternal anti-water filter
POWER SUPPLY AND AUTONOMY
Power supplyEnvironmentally friendly rechargeable NiMh batteries without memory effect
Autonomy5 hours under standard operating conditions
CERTIFICATIONS AND DEGREE OF PROTECTION
CertificationsCE according to Declaration of ConformityIP 54
CALIBRATION
Calibration Periodicity12 months with issue of Calibration Certificate (ISO standard)
Calibration ModesAccording to Gastech operating procedure with Rivoira certified sample gases
OPERATING CONDITIONS
Operating Temperature-20 to +50°C / 0 to 85% R.H. non-condensing
DIMENSIONS AND WEIGHT
Dimensions200x80x120 mm
Weight2000 gr
OPTIONAL ACCESSORIES

EA.0010.8005Road surface search probe for tracer gas detector
EA.0010.8020Bell probe for uneven surface search for tracer gas detector